Heat and mass transfer mathematical model is formulated. Solution of the moisture transfer equation was obtained by discrete-continuum approach, which gives an opportunity to obtain the new analytical solution. Algorithm for calculating the moisture regime according to the proposed mathematical model is given. Enclosing structure with aerated concrete base and expanded polystyrene insulation is chosen for moisture regime calculation. Moisture behaviour calculation is done in three construction areas (dry, normal, wet) for four different moisture regimes of building room (dry, normal, moist, wet). Calculation results were summarized in a table which engineers can use in their practical work.
Сформулирована математическая модель тепловлагопереноса. Получено решение нестационарного уравнения влагопереноса с помощью дискретно-континуального подхода, что дало возможность вывести новую аналитическую формулу. Приведен алгоритм расчета нестационарного влажностного режима по предложенной математической модели. Для расчета влажностного режима выбрана ограждающая конструкция с основанием из газобетона и утеплителем из пенополистирола. Проведен расчет влажностного режима в трех зонах влажности (сухая, нормальная, влажная) для четырех различных влажностных режимов помещения здания (сухой, нормальный, влажный, мокрый). Результаты расчетов сведены в таблицу, которую возможно использовать в практической инженерной работе.