Comparative characteristics of facial scanners; Сравнительная характеристика лицевых сканеров в эксперименте

The development of digital technologies and devices used in orthopedic dentistry makes it possible to reduce the time for making a prosthesis, reduce costs and improve the quality of manufactured prostheses. One of the most important stages in the production of a prosthesis in a digital protocol is the stage of obtaining digital impressions, which must be as accurate as possible. Goal — to experimentally evaluate the accuracy of three-dimensional images and determine the most suitable models of facial scanners, optimal in terms of price and quality ratio. Materials and Methods. The study examined four scanner models: 3dMDface, ObiScanner, Einstar, and Planmeca ProMax 3D ProFace. The reference model chosen was the stationary scanner VT MINI V2 (Volume Technologies, Russia). A facial mannequin with areas of textured surface was used, and specific points (grooves, indentations) were selected, as these points could be reproduced across different scans: points 1 and 2 represent the outer corners of the eyes, points 3 and 4 correspond to the corners of the mouth, and point 5 indicates the chin. All obtained images were imported into the Exocad software, where each scan was sequentially overlaid onto the reference model scan, and the distance between the scans was measured. Five such studies were conducted for each scanner. Results. The ObiScanner demonstrated the least deviation from the reference scan at a greater number of points: point 1 — 0.069 mm; point 4 — 0.015 mm; point 5 — 0.045 mm, and it is also acceptable in terms of price and availability. The Planmeca ProMax 3D ProFace scanner showed the least deviation from the reference scan at point 3 (0.008 mm), but it is the most expensive among the scanners involved in the study. The 3dMDface scanner had the least deviation at point 2 (0.068 mm) from the reference, but it is the most difficult to access and the second most expensive among the scanners in the study. The Einstar scanner exhibited higher deviation values from the reference scan at each point compared to the other scanners involved in the study, but it has the lowest cost and is easily accessible for purchase. © 2025 Elsevier B.V., All rights reserved.

Издательство
Clinical Dentistry LLC
Номер выпуска
1
Язык
Russian
Страницы
110-114
Статус
Published
Том
28
Год
2025
Организации
  • 1 The Prosthetic Dentistry Department, Russian Federation
  • 2 The Dentistry Department, Russian Federation
  • 3 The Institute of Digital Dentistry, Russian Federation
  • 4 RUDN University, Moscow, Russian Federation
Ключевые слова
additive technologies; digital dental technologies; facial prostheses; facial scanners; scanning accuracy
Цитировать
Поделиться

Другие записи

Avatkov V.A., Apanovich M.Yu., Borzova A.Yu., Bordachev T.V., Vinokurov V.I., Volokhov V.I., Vorobev S.V., Gumensky A.V., Иванченко В.С., Kashirina T.V., Матвеев О.В., Okunev I.Yu., Popleteeva G.A., Sapronova M.A., Свешникова Ю.В., Fenenko A.V., Feofanov K.A., Tsvetov P.Yu., Shkolyarskaya T.I., Shtol V.V. ...
Общество с ограниченной ответственностью Издательско-торговая корпорация "Дашков и К". 2018. 411 с.