A discrete-continuous approach was applied to the moisture transfer equation, which made it possible to obtain an analytical solution for the moisture potential. The new method was applied to study the unsteady-state moisture regime of the facade heat-insulating composite system with expanded polystyrene insulation and aerated concrete base. It was found that the mass moisture content of building materials achieved in the walls during the period of operation is lower than the mass moisture content used in construction regulations, which makes it possible to increase the accuracy of calculating the transmission heat losses of the building. Calculations of heat losses of a two-storey building in the climatic conditions of Moscow (Russia) showed a decrease in the heating system load by 5 %, and the reduction in heat losses for specific premises of the building ranged from 3.6to7 %.
К уравнению влагопереноса применен дискретно-континуальный подход, позволивший получить аналитическое решение для потенциала влажности. Новый метод был применен для исследования нестационарного влажностного режима системы фасадной теплоизоляционной композиционной с утеплителем из пенополистирола и основанием из газобетона. Было получено, что массовая влажность строительных материалов, достигаемая в стенах за период эксплуатации ниже массовой влажности, используемой в нормативных документах по строительству, что дает возможность повысить точность расчета трансмиссионных тепловых потерь здания. Расчеты тепловых потерь двухэтажного здания в климатических условиях г. Москвы (Россия) показали снижение нагрузки на систему отопления на 5 %, а для конкретных помещений здания снижения тепловых потерь составило от 3.6 до 7 %.